What Should I Do if a Roof Inspector Issues a Correction Notice?
Treat the written correction notice as controlling: keep the permit, notice, approved plans, and reinspection instructions; have the responsible contractor or qualified professional map each item to the adopted local code and exact metal-system instructions, correct the items, preserve dated evidence, then request reinspection.
What specific steps should I take after receiving a correction notice?
- Exact wording
- Separate an observed condition from the required remedy. Quote the notice, ask the issuing office what controls, and do not replace a specific correction with a generic roof check[1][4].
- Local code and amendments
- The model IRC is a starting point; the AHJ’s adopted edition, amendments, approved plans, and written variances control. Confirm them locally[2][4].
- System instructions
- Compare the correction with current instructions for the exact profile, underlayment, fasteners, flashing, slope, and accessories. Metal panels must follow manufacturer instructions[2][3].
- Visibility and evidence
- Do not conceal an approval-required item prematurely. Keep dated photos, product data, invoices, and scope changes; records do not replace a required field inspection[1][3].
- Readiness and responsibility
- Follow the department’s request route and make the site ready. The installer explains its work; the AHJ decides acceptance[1][4].
| Stage | What to confirm | Evidence to keep | Who acts |
|---|---|---|---|
| Notice received | Every cited item, permit number, deadline, and contact route | Original notice and inspection record | Owner and contractor[1][4] |
| Scope resolved | Code edition/amendment, approved plans, and specified system instructions | Marked scope, product documents, and change records[2][3] | Contractor; AHJ clarifies code questions[2][4] |
| Correction visible | No cited work is concealed before approval where the AHJ requires visibility | Dated photos and invoices; keep access coordinated[1] | Contractor and owner[1] |
| Reinspection requested | Request method, notice period, readiness, and any fee | Request confirmation and updated inspection record[1][4] | Permit applicant or authorized agent[1][4] |
When metal makes sense
- The correction can be matched to current, product-specific installation instructions and approved details[2][3].
- The owner and installer can preserve the cited work and assemble a clear permit record before review[1].
- The AHJ confirms the correction path, including any requested evaluation report or tested-assembly documentation[2][5].
When it is not recommended
- Do not treat the project as complete while a correction remains open or the AHJ has not accepted the response[1][4].
- Do not select a different product to avoid a cited detail or substitute a generic internet detail for system instructions[2][3].
- Pause for written clarification when the notice, plans, product documents, or responsible parties conflict[2][4].
- Metal is not an immediate answer to concealed structural, moisture, or life-safety conditions requiring site evaluation; this page cannot diagnose them remotely.
This educational page does not replace the issuing authority’s written correction notice, adopted code, permit file, inspection record, manufacturer instructions, or advice from an appropriately qualified local professional. It cannot diagnose an unseen roof, direct unsafe access, interpret legal or insurance rights, or guarantee reinspection approval.