Vermilion County, Illinois
Metal Roofing in Fithian, IL
Metal roofs for Fithian's 1950s-era housing, matched to the hail, wind and zone 5A winters recorded here.
Bishop's Metal Roofing installs Stone-Coated Steel Shingles and Standing Seam Metal Roofing on Fithian, IL homes, and with 4 days of 1-inch-plus hail and 21 days of 58-mph-plus wind within 10 miles from 2016 through 2025, the detail to get right here is ice-barrier underlayment and snow retention for zone 5A winters.
- Population
- 4742025 Census estimate
- Median home built
- 1958ACS 2020–2024
- 1-inch hail days
- 4Within 10 mi, 2016–2025
- Climate zone
- 5AIECC 2021
Local roof brief
What should you check before putting a metal roof on a home in Fithian?
Fithian’s combination of winter climate zone 5A and a county record of 9 winter-storm event days means ice-barrier underlayment at eaves and attention to snow retention above entries should be part of planning. The village recorded a highest estimated wind of 81 mph and 21 severe-wind days within 10 miles, so edge, rake and ridge fastening details matter for wind uplift. Housing stock has a median year built of 1958 with 55% of homes built before 1960, making deck inspection and the possibility of a full tear-off more likely. Hail within 10 miles included four 1.0-inch days and a largest reported dime-to-quarter event of 1.75 inches, so consider impact-rated products tested to UL 2218 Class 4. For Fithian’s largely single-family detached neighborhood, Stone-Coated Steel Shingles often fits the local roof lines and neighborhood appearance better, while Standing Seam suits simpler roof planes and modern profiles. Bishop's Metal Roofing can discuss both choices on-site.
What it means
How should Fithian's storm and housing record shape your roof?
- Snow load: plan retention and ice barrier
Fithian is in IECC climate zone 5A, and Vermilion County recorded 9 winter-storm days from 2016 through 2025. Snow leaves a metal roof in sheets, so mark the doors, walks and lower roofs that need snow retention, and confirm ice barrier at eaves and valleys.
- Older homes: plan the tear-off and deck check
Half of Fithian's 240 housing units were built in or before 1958, and 55% predate 1960. Roofs that age often hide extra shingle layers, plank decking with gaps and undersized ventilation. Expect a full tear-off, deck repairs priced per sheet, and an intake-and-exhaust ventilation plan in the scope.
- Wind: ask about edge fastening
NOAA recorded 58-mph-plus wind within 10 miles of Fithian on 21 days; the top gust, 81 mph (estimated), came on August 16, 2025. That peak matches hurricane-force speed. 7 tornado tracks passed within 10 miles; the strongest was rated EF2 on September 9, 2016. Roofs fail at the edges first in wind like that; get the eave, rake and ridge fastening schedule and the assembly's uplift rating in the scope.
- Hail: know the local stone size
Within 10 miles of Fithian, hail of at least 1 inch fell on 4 days from 2016 through 2025, and the largest report was 1.75 inches on May 16, 2019. April has the most reports in the local record. The most recent 1-inch event was February 27, 2023. 2 days reached 1.75 inches (golf-ball size), large enough that a UL 2218 Class 4 impact rating is worth asking for. Hail and impact ratings explained.
- Long ownership favors a last roof
84% of homes in Fithian are owner-occupied. If you plan to stay, compare one metal roof against the two or three asphalt roofs the same 50 years would otherwise take. Compare lifetime cost.
Roof report
The Fithian roof record: storms, climate and homes
| Days with hail 1 inch or larger | 47 reports |
|---|---|
| Days with hail 1.75 inches or larger | 2 |
| Days with hail 2 inches or larger | 0 |
| Largest hail reported | 1.75 inMay 16, 2019 |
| Most recent 1-inch hail | February 27, 2023 |
| Peak hail month | April |
| Days with wind 58 mph or stronger | 2147 reports |
|---|---|
| Highest wind | 81 mphEstimated, August 16, 2025 |
| Tornado tracks within 10 miles | 7Strongest EF2, September 9, 2016 |
| IECC climate zone | 5ACold, moist |
|---|---|
| Winter-storm days (Vermilion County) | 9 |
| Ice-storm days (Vermilion County) | 0 |
| Median year built | 1958 |
|---|---|
| Built before 1960 | 55% |
| Built before 1980 | 73% |
| Built 2000 or later | 19% |
| Median home value | $118,000 |
| Housing units | 240 |
| Owner-occupied | 84% |
| Single-family detached | 91% |
Storm counts are NOAA Storm Events reports within 10 miles of Fithian's Census center point, January 2016 through December 2025; winter days are coded to Vermilion County. Reports depend on spotters and population, so rural totals run low. How we measure.
Two systems
Which of the two metal systems works best in Fithian?
Stone-Coated Steel Shingles in Fithian
Steel panels with a bonded stone granule finish that look like shingles, shake or tile. The natural fit for traditional pitched roofs, HOA neighborhoods and owners who want a familiar look with a steel core.
Standing Seam Metal Roofing in Fithian
Continuous vertical panels with raised, concealed-fastener seams. The fit for clean modern lines, farmhouse and lake homes, low-slope sections and fast snow shedding.
Community
About Fithian, Illinois
Fithian is an incorporated village in Vermilion County, Illinois; the U.S. Census Bureau identifies it as “Fithian village, Illinois.” The county notes flooding risks in low-lying areas and near streams, creeks, and rivers and records localized drainage problems.
Community sources: U.S. Census Bureau, Fithian village, Illinois profile · U.S. Census Bureau, Illinois Incorporated Places (2024) · Vermilion County Floodplain Management · Illinois Flood Maps, Vermilion County Flood Hazard Information · FEMA Flood Maps
FAQ
Fithian metal roofing questions
How hard does severe wind hit Fithian roofs?
Severe wind events within 10 miles have included 21 days with 58+ mph winds and an estimated peak wind of 81 mph. That frequency and a highest estimated gust of 81 mph indicate uplift-resistant fastening and edge details should be part of roof planning.
Should metal roofs in Fithian have snow guards and ice-barrier underlayment?
Yes—Fithian lies in IECC climate zone 5A and Vermilion County logged 9 winter-storm event days from 2016–2025, so use ice-barrier underlayment at eaves and consider snow retention above entries where snow sheds could create hazards.
Will an older house in Fithian need structural work for a metal roof?
Possibly, but many homes are older: median year built is 1958 and 55% were built before 1960, so a deck inspection is recommended and a full tear-off may be necessary if decking or multiple layers exist to ensure a proper metal installation.
Stone-Coated Steel or Standing Seam — which fits Fithian houses better?
Stone-Coated Steel often suits Fithian’s housing because 91% of units are single-family detached and neighborhood rooflines tend to match shingle-like profiles; Standing Seam is a good match for simpler roof planes or modern designs.
Nearby
Communities near Fithian
Consultation
Schedule your Fithian roofing consultation
Tell us about the house. We'll inspect the roof, recommend Stone-Coated Steel or Standing Seam for it, and put the scope, warranty and financing options in writing.